Velocity Edge GX440 Betriebsanleitung Seite 102

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 530
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 101
Electrical installation
4.9 Other connections
Drive converter cabinet units
102 Operating Instructions, 10/2008, A5E00288214A
4.9.18 SMC20 Sensor Module Cabinet-Mounted (option K48)
4.9.18.1 Description
Description
The SMC20 Sensor Module is used for determining the actual motor speed and the path
length. The signals emitted by the rotary pulse encoder are converted here and made
available to the closed-loop controller via the DRIVE-CLiQ interface for evaluation purposes.
The following encoders can be connected to the SMC20 Sensor Module:
Incremental encoder sin/cos 1Vpp
Absolute value encoder for EnDat and SSI (with 5 V operating voltage)
3URWHFWLYHFRQGXFWRUFRQQHFWLRQ
01P
/('
;
(QFRGHUV\VWHPLQWHUIDFH
;
'5,9(&/L4LQWHUIDFH
;
(OHFWURQLFVSRZHUVXSSO\
Figure 4-19 SMC20 Sensor Module
Seitenansicht 101
1 2 ... 97 98 99 100 101 102 103 104 105 106 107 ... 529 530

Kommentare zu diesen Handbüchern

Keine Kommentare